Port: | Shenzhen |
Payment Terms: | L/C,T/T,Western Union,MoneyGram |
Supply Ability: | 5000 Set/Sets per Year |
Speed: | 1500/1800rpm |
Place of Origin: | Guangdong China |
ISO: | 9001:2000 & 14001 &18000 |
Output Type: | AC Three Phase |
Color: | Orange red |
Ignition: | Altronic |
Alternator: | Leroy Somer, Stamford |
Control panel: | GU620, ComAp, Deepsea |
Model Number: | H series |
Rated Voltage: | 220V~480V |
Brand Name: | CAMDA |
Air intake: | natural or turbocharger |
Oil type: | Higher than 15W-40 |
Frequency: | 50/60hz |
Rated Current: | 40A~1200A |
Rated Power: | 20KW~500KW |
Voltage fluctuation: | +-5% |
Fuel type: | natural gas, biogas, coal bed gas,landfill gas |
Certificate: | CE |
Delivery Detail: | 45 days upon receipt of downpayment |
Packaging Detail: | Membrane for generator set and case for standar accessories |
Camda Biogas Generator Set / Natural Gas Generator Set from 25KW to 500KW
Advantages for CAMDA gas engine
1.Adopt Cummins engine block,so the instructure is very strong. Also it is easy for customer to get maintenance spare parts.
2. Adopt advanced Hall ignition sensor and Highly capable USA Altronic ignition system, the engine ignition will be more reliable and easier to start. Besides,there is Top End Center mark on the engine,it is easy for users to adjust the top end certer when commissioning generator set.
3 Adopt ComAp Interligen/Interlisys controller to make synchronization for generator set, all the parameters can be set in the program and can realize the remote controlling through cell phone or computer.
4.The gas inlet pressure is only 2~12kPA,so almost all city pipe gas pressure can be satisfied,not to mention biogas. So there is no need for customer to install blower to increase pressure and save cost for you.
5. Electrical Air/Gas mixer. The mixer guarantees optimum air-fuel ratio to improve efficiency and reduce NOx emission. Unique air-fuel ratio adjusting system is suitable for 30%~90% methane concentration.
6. Long designed overhaul term: 25000~30000 hours
7. Comply with CE standard, ISO9001:2008 quality management system, ISO14001:2004 and OHSAS 18001:2007.
Standard working conditions
1.Atmospheric Pressure:100kPa,Ambient Temp:20°C, Relative Humidity:30%.
2. Ambient Temp-40°C~+40°C, Relative Humidity<90%(20°C),Altitude≤1000mabove sea level.
Controller Introduction
1. Controller model: IG-NT
2. CHP support (programmable PID loops and other built-in PLC functions)
3. Support of engines with ECU (J1939, ModBus and other proprietary interfaces); alarm codes displayed in text form
4. Automatic synchronizing and power control (via speed governor or ECU)
5. Baseload, Import/Export, TempByPower
6. Peak shaving
7. Voltage and PF control (AVR)
8. Generator measurement: U, I, Hz, kW, kVAr, kVA, PF, kWh, kVAhr
9. Mains measurement: U, I, Hz, kW, kVAr, PF
10. Selectable measurement ranges for AC voltages and currents – 120 / 277 V, 0-1 / 0-5 A
11. Inputs and outputs configurable for various customer needs
12. 2x RS232/RS485 interface with ModBus protocol support; Analog/ GSM/ ISDN/CDMA modem communication support; SMS messages; ECU ModBus interface; secondary RS485 converter is isolated
13. Event-based history (up to 1000 records) with customer-selectable list of stored values; RTC; statistic values
14. Integrated PLC programmable functions
15. Interface to remote display units (3x IS-Disp), together with IG-IB module can connect to internet.
16. USB 2.0 slave interface
17. Dimensions 284x180 mm (front panel)
18. Sealed to IP65
Scope of supply
1. Brand new Gas engine with necessary parts.
2. Brand new Leroy Somer AC brushless alternator IP23
3. Rating: 3 phases 4 lines. 380/220V,400/230V,415/240V,220/127V,440V,480V, 50 HZ or 60HZ, 1500rpm or 1800rpm, 0.8PF, IP23, Insulation class H.
4. Standard Automatic Control Panel (If you need to synchronize generator set with national grid,please inform us and we will provide special controller)
5. Main Line Circuit breaker
6. Standard Cooling system: Water Radiator (If you need CHP system,please inform us)
7. Mixer.
8. Ignition system,including:ECU, Spark plug, High-voltage electricity wire;Ignition switch,Ignition coil;Wires.
9. Electron speed regulator,including controller and actuator.
10. Air filter.
11. Silencer.
12. Flame arrester.
13. Battery, battery charger, Battery cable, Battery tray and necessary accessaries
14. Gas pressureadjusting valve.
15. Automatic lube oil filling equipments
Technical data for gas engine supply
Genset model | Prime power (KW) | Engine model | Alternator model |
KDGH25-G | 24 | HG4B | LSA42.3VS3/25.6KW |
KDGH30-G | 30 | HG4B | LSA42.3S4/28KW |
KDGH50-G | 50 | HG6B | LSA43.2L9/48KW |
KDGH60-G | 60 | HG4TG | LSA43.2L65/56KW |
KDGH84-G | 84 | HG6TJ | LSA44.2VS45/84KW |
KDGH120-G1 | 120 | HG6TG | LSA44.2M95/120KW |
KDGH120-G | 120 | HGN14 | LSA44.2M95/120KW |
KDGH150-G | 150 | HGNT14 | LSA46.2M5/160KW |
KDGH200-G | 200 | HGNT14 | LSA46.2L6/200KW |
KDGH250-G | 250 | HGKT19 | LSA46.2VL12/252KW |
KDGH300-G | 300 | HGKT19 | LSA47.2VS2/300KW |
KDGH500-G | 500 | HGKT38 | LSA49.1S4/528KW |
Biogas treatment system for 25KW~500KW biogas generator
Biogas generator pictures