10-25kw Monobloc AC Air Source Heat Pump for heating & cooling system freestanding Installation free hot water air heatpump

$2,500.00
Min. Order
5 Pieces
Choose your specifications
Company Information

Foshan Longkai Energy Saving Equipment Co., Ltd.

CN Manufacturer
Response Time
<24h
Response Rate:
57.1%
Transactions
---
2 Years Paid Supplier Gold Supplier Onsite Check Trade Assurance
Learn More

Quick Details

Port: guangzhou port, gaoming port
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram,Transfer
Storage / Tankless: Storage
Installation: Freestanding
Place of Origin: Guangdong China
Warranty: None
Customizable: YES
Heating Capacity/btu: 12,624-27,294 BTU/h
Heating Capacity: 10-25 kw/h
Power Source: Gas
Rated Hot Water Temperature: 55℃
Use: House, Small Office, hotel
Housing Material: Stainless Steel, Color Steel
Refrigerant: R22/ / R410
After-sales Service Provided: Free spare parts
Model Number: TL-WHCTOP1-0
Cooling Capacity: 9-21 kw/h
Certification: CE,CCC
Brand Name: Longkai
Type: Air Source Heat Pump
Compressor Brand: Copeland ZW
Voltage: 220v/380v 50/60Hz
Working Ambient Temperature: -5~40℃/ -25~40℃
Cooling Capacity/btu: 30,000-71,000 BTU/h
Application: Outdoor,Hotel,Commercial,Household
Packaging Detail: waterproof-film and wooden mount
Package Preview: https://sc01.alicdn.com/kf/HLB1ebtPazvuK1Rjy0Faq6x2aVXar.jpg_640x640.jpg,https://sc01.alicdn.com/kf/H78644cac409e49dfbc7c3a8cd66fc4031.jpg_640x640.jpg
Products Description
The air energy heat pump
The air energy water heater absorbs the low-temperature heat in the air, gasifies the fluorine medium, pressurizes and heats up the air after being compressed by the compressor, transforms the water supply and heats up through the heat exchanger, and then heats the water temperature with the compressed high-temperature heat.
Product Name
Top fans air energy heat pump
Color
Gray, Silver
Heating Capacity
10-25 kw/h (34,000-85,000 btu/h)
Cooling Capacity
9-21 kw/h (30,000-71,000 btu/h)
Fanction
 Heating, Cooling
Water temperature
55℃/ 131℉
Applicable place:
hot water supply, heating and cooling for hotels, hotels, families, offices, factories, schools, dormitories and hospitals.
Product Features
it is composed of compressor, air heat exchanger, water heat exchanger, throttling element, controller and other components. According to the principle of inverse Carnot cycle, the compressor is driven by a small amount of electric energy, and the air heat source above - 10 ℃ in the air is transferred to the air heat exchanger through the heat absorbing working medium, which causes the heat generated by the heating, heating and gasification of the working medium in the air exchanger to be released to In the water heat exchanger, the water temperature in the water tank is raised by the circulating water pump, and stored in the water tank for the user to use at any time. At the same time, the heat storage tank can be configured according to the user's demand.
Product Inclusion
Air Source Heat Pump
The air energy water heater absorbs the low-temperature heat in the air, gasifies the fluorine medium, pressurizes and heats up the air after being compressed by the compressor, transforms the water supply and heats up through the heat exchanger, and then heats the water temperature with the compressed high-temperature heat.
Buffer water tank
Buffer water tank is the water storage technology of air-conditioning system, which increases the water quality of small-scale system. It can effectively solve the problems of load fluctuation caused by small system and frequent start-up of main engine, so as to extend the service life of equipment, save energy and power.
Intelligent control panel
Full automatic temperature control, intelligent fault automatic detection, over pressure, grounding, over temperature, anti freezing and other protection functions。
Centrifugal pump
Simple structure, few parts, few faults, durable, less maintenance cost, convenient management and stable operation
304 stainless steel pipe
Environmental protection, health, wear resistance, low temperature resistance, excellent thermal expansion performance and insulation performance。
Product Show
Product Paramenters
TK-HCTOP1-0
Model No.
LK-3HPS
LK-5HPS
LK-6HPS
LK-7HPS
Power voltage
V/50Hz
220/ 380
22O/380
22O/380
380
Heating capacity
kw/h
10.08
18.1
21.6
25
btu/h
34,391
61,754
73,695
85,295
Cooling capacity
kw/h
9
15
18
21
btu/h
30,706
51,177
61,412
71,648
Rated input power
kw/h
2.73
4.85
5.88
6.85
Rated input current
A
12
8
10.44
13.44
Max input power
kw/h
3.65
6
7.3
7.3
Max input current
A
15
12
13
16
Rated water volume
L/h
260
410
520
560
Weight
kg
100
140
170
160
R22 capacity
g
1400
2300
2500
3800
Demension(WxDxH)
mm
700*655*850
820*780*1040
Max hot water temperature
60℃/ 140℉
Rated hot water temperature
55℃/ 131℉
Outlet rated pressure
2.7mPa
Max pressure/min pressure
2.7mPa/0.1mPa
Inlet rated pressure
0.8mpa
Working Ambient temperature
 -25~40℃
Rated of waterproof
IPX4
Anti electric shock
I
If you need to purchase another model or change the configuration, please contact customer service customize.
Main Accessories
Model No.
LK-3HPS
LK-5HPS
LK-6HPS
LK-7HPS
Suggested cycle water pump and rated water flow
Pum-102EH/ 5.0m³ (without)
Pum-200EH/ 7m³ (without)
Pum-200EH/ 8m³ (without)
Pum-400EH/ 9m³ (without)
Heat exchanger
Pure Copper 6 spiral casing
Compressor
Copeland ZW
Electric control
Intelligent&LED
Pipe Size Connector Size
DN25-1inch male
Evaporator
9.52 internally ribbed tube L type
Throttle type
electronic expansion valve
Color
Gray, White
Packaing
waterproof-film and wooden mount

Compressor of TOSHIBA or Copeland

Copeland flexible scroll compressors from the United States, ultra-high energy efficiency ratio, high volumetric efficiency, high
thermal insulation efficiency, low noise, reliable scroll compressor operation.

Titanium evaporator

Titanium evaporator has outstanding advantages such as high specific strength, good corrosion resistance and high temperature
resistance.

Efficient tank heat exchanger

The high-efficiency heat exchanger which makes the system safe water temperature reach 60 degrees, small coolant circuit clips,
reduce oil accumulation. no internal joints, reduce refrigerant leaks. and self-cleaning capabilities, making the unit long
Efficient operation.

Four-way reversing valve

By changing the refrigerant flow channel and the refrigerant flow direction, the functions of the indoor and outdoor units of the
air conditioning system in winter and summer are changed.

Electrical expansion valve

Famous Japan Saginomiya electrical expansion valve,It can regulate automatically from 0 to 500 rank that make the system to run in
a stable state and reduce trouble.

Economizer

The economizer supplementary air cycle can improve the efficiency of the single-stage screw compression refrigeration cycle,
increase the cooling capacity, and reduce the compressor exhaust temperature

Heat pump knowledge and FAQ
1. What is a heat pump? What kinds of heat pumps are divided into? Which parts are mainly composed of?
Heat pump is a kind of efficient heat transfer equipment. It can obtain low-grade heat from air, water or soil, and output high-grade heat through the work of electric driven compressor. According to different heat sources, heat pump can be divided into three types: air source heat pump, water source heat pump and ground source heat pump. The heat pump is mainly composed of compressor, condensation system, throttling system, evaporation system and intelligent control system.
2. Why can heat pumps save energy?
Heat pump is to carry heat through electric driven compressor, which needs to remove a small amount of electricity during operation. It consumes 1 unit of electricity and can carry 2-10 times the heat of electricity, so it can greatly save energy. The heat pump water heater can also use the low price of electricity to produce hot water and store it in the heat preservation water tank, which can save energy and cost.
3. What are the advantages of heat pump water heater compared with traditional water heater?
The heat pump water heater is a low-carbon energy-saving product, which has the advantages of high efficiency, energy saving, safety and reliability, green environmental protection, intelligent and durable. It can be used 24 hours a year, free from the bad weather such as overcast, rain, snow and night, and does not produce any exhaust gas, waste water, waste residue discharge. The operation cost of heat pump water heater is only 1 / 4 of that of electric water heater and 1 / 3 of that of fuel oil and gas water heater.
4. What industries and places are heat pumps suitable for?
Heat pump can be used as domestic hot water heating equipment and industrial production heating equipment. Domestic hot water applications such as family, villa, school, hospital, factory dormitory, hotel, restaurant, restaurant, beauty salon, swimming pool, living area heating and other dormitory hot water supply. Heating for industrial production such as electroplating, bleaching and dyeing, drying and other industrial purposes.
5. Is there any difference between heat pump and solar water heater?
Solar water heater must rely on direct sunlight or radiation to achieve the heating effect, while heat pump is to absorb heat from air, water or soil and exchange heat with water to achieve the heating effect
6. Selection standard of hot water heat pump unit
In winter, the hot water consumption is the largest. Generally, the selection of heat pump hot water unit is based on the coldest weather and the largest water consumption in winter. The longest running time of the unit is not more than 16 hours. The total hot water consumption is calculated as follows: shower 5L / person; bathtub 300L / person; bucket 3L / person; hair salon shampoo 30 / person; hotel 15) l / room. The configuration ratio of main machine and water tank in the south is 1:0.9 ~ 0.7. The configuration ratio of main machine and water tank in the north is 1:0.7 ~ 0.5.
7. Selection standard of heating heat pump hot water unit
In winter, the heat of the heating thunder is the largest, and the selection of the hot water unit of the heat pump is generally based on the coldest weather in winter. The longest running time of the unit is not more than 16 hours. Reference model of heating area: 3P with 6 square meters; 5p with 100 square meters; 10p with 200 square meters; 15p with 280 square meters; 20 with 400 square meters. The reference factors for heating are the lowest ambient temperature in winter, the temperature needed in the room, the degree of heat preservation of the house, the purpose of the house, etc. Floor heating pipe and fan coil can be used for indoor heating, and special attention shall be paid not to use radiator. Because the radiator is made of cast iron, the heat transfer temperature difference is large, resulting in temperature rise. Such low efficiency of heat transfer will result in energy saving and waste of electric energy. This will also lead to rust, and rust will be attached to the water heat exchanger of the air energy heat pump host, which will reduce the heat transfer efficiency and host life, and will block the filter, which will cause the host alarm to stop working.