$16.00
Min. Order : 100 Pieces
$15.00
500-999 Pieces
$14.00
1000-2999 Pieces
$13.00
≥3000 Pieces

Amazon hot selling LCD digital display breathing for alcohol tester

Note: Please be cautious and check with your supplier if this product is for virus protection purposes and if the coronavirus (COVID-19) will affect your order.
Trade Assurance
Built-in order protection service in alibaba.com
Product quality
On-time shipment
More on shipping and other trade services.

Quick Details

Brand Name: ACT
Place of Origin: Hunan China
Sensor type: Semiconductor Sensor
Detection Range: 0.00~2.00‰BAC/0.000~0.200%BAC/0.000 ~1.000mg/L
Dimensions: 145*58*33.5mm
Optimal operating temperature: 0°C~50°C
Blowing Time: About 5 seconds (adjustable)
Sensor Accuracy: ±0.008 at 0.050% BAC;>0.050% BAC: ±20%
Reference standard: EN 16280
Model Number: ACT618
Weight: 75g
Power Supply: 3*AAA alkaline batteries
Display: About 2.0 inch LCD(blue film)
Packaging Detail: Unit N.W/Size: 195g/175*86*62mm Inner Pakcing: gift box Qty per Carton: 90pcs Carton Meas: 47*40.5*47.5cm G.W/Carton:About 19.8kg
Selling Units: Single item
Single package size: 17.5X8.6X6.2 cm
Single gross weight: 0.195 KG
Package Preview: https://sc04.alicdn.com/kf/H02c5ef9bb64849898a1ab947ab5a0566p.jpg_640x640.jpg
Changsha U De Toptech Electronic Technology Co., Ltd.
Gold Supplier
CN
Trading Company
≤2h
Response Time
100.0%
On-time delivery rate
US$ 50,000+
24
Transactions
Visit Store
Product Description
Item
Specifications
Sensor
Semiconductor Sensor
Response Time
3-5 seconds
Blowing Time
About 5 seconds (adjustable)
Reference Standard
EN16280
Product Certificate
CE


Detection Range
0.00~2.00‰BAC;
Or 0.000~0.200%BAC;
Or 0.000 ~1.000mg/L;
(if ‰BAC and mg/L convection factor is 2.0)
i.e. 0.50‰BAC = 0.050%BAC = 0.250mg/L
Sensitivity
0.001% BAC
Sensor Accuracy
±0.008 at 0.050% BAC;>0.050% BAC: ±20%
Display
About 2.0 inch LCD(blue film)
Power Supply
3 × AAA alkaline batteries
OOptimal Operating Temperature
0°C~50°C
Dimensions
145*58*33.5mm
75Net Weight
54g
Packing Accessories
5* mouthpieces /1* user manual /1* gift box

Product features:

1.Key parameters such as sampling analysis, test accuracy and display range designed according to the EN 16280 standard, which drafted and officially adopted by the European Union in the field of breath alcohol testing devices used by the general public in the year of 2012.
2.Designed with breath monitoring module, dynamically monitor the continuity of breath sampling, so that the test result will more accurately reflect the Blood Alcohol Content (BAC) of human.
3.Units setting (2 software version for option):
1)Version 1: mg/L, ‰, %, unites can be switched freely by user.
2)Version 2: factory fix set the unit according to customer's requirement before shipment, end user cannot reset the        unit.
4.Max memories: max 5 test records be stored.

5.Low voltage warning.
6.Sound warnings that exceed preset criteria
7.Simple and portable curve bar appearance design, easy use.

Warm Tips:

1.It takes certain amount of time for the alcohol in stomach to be absorbed into blood. To get a more accurate test result which can reflect the Blood Alcohol Content well, please abstain from smoking and drinking (for at least 20 minutes) before test.
2.While doing breath sampling test, blowing cannot be interrupted (keep blowing about 5s). Blowing time is too short, the alcohol molecules in the blood cannot spread to the lungs completely, then test results will have a big difference from the blood alcohol content.
Our Company

We are U de Toptech Technology Company,specializing in the research, development, production and sales of alcohol testers. The core R&D team has 10 years of R&D and production experience in the alcohol tester industry.We have a number of computer software copyrights and authorized patents in the corresponding fields.

Our product core calibration equipment was imported from Germany, the simulator for production and test was imported from USA . At present, the company has developed and mass-produced several types of semiconductor and fuel cell alcohol testers, and exported to Europe, the United States, Japan, Southeast Asia, etc.

FAQ

Q1.Why use clear water or non-alcoholic drink before the test?
A:
Residues of alcohol in mouth will affect the measured values, to get test results which reflect the human Blood Alcohol content accurately, please rinse out your mouth with water or non-alcoholic drinks to remove the residues of alcohol in mouth before using the unit.

Q2.Why do you test about 20 minutes after drinking?
A:
It takes certain amount of time for the alcohol in stomach to be absorbed into blood. To get a more accurate test result which can reflect the Blood Alcohol Content well, please abstain from smoking and drinking (for at least 20 minutes) before test.

Q3.Why does the test result fluctuate between two adjacent tests when the same person is tested on the same instrument for alcohol testing?
A:
After drinking alcohol, alcohol is absorbed into the bloodstream from the stomach. As time goes by, the alcohol in the blood will be absorbed and digested. Alcohol is metabolized in the liver. Adult healthy liver can decompose about 10mL-20mL per hour of alcohol, so the blood alcohol content (BAC) may fluctuate within a few minutes.

Q4.Two people drink the same amount of alcohol, why is the result of the alcohol test different?
A:
Tolerance to alcohol varies from one person to another, and can be affected by such factors as genetics, constitution, gender, percentage of body fat, adaptation to chronic alcohol use, and synergistic effects of drugs. same amount of alcohol, different person the Blood Alcohol Content maybe different, so the test result maybe different.