Full protection digital LCD display UPS power supply 2000VA 1200W for education institute

$61.24 - $64.96
Min. Order
100 Pieces
Quick Quotation
Company Information

Shenzhen Fenice Power Technology Co., Ltd.

CN Manufacturer
Response Time
<24h
Response Rate:
89.5%
Transactions
US$ 6,000+
5 Years Paid Supplier Gold Supplier Onsite Check Trade Assurance
Learn More

Quick Details

Port: Shenzhen
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability: 50000 Piece/Pieces per Month
Place of Origin: Guangdong China
Brand Name: OEM/ODM
Model Number: ST2000
Phase: Single Phase
Protection: Short Circuit
Weight: 11.3KG
Output Voltage: 110/120/220/230/240VAC
Type: Line Interactive
Application: Instrumentation
Capacity: 2000VA/1200W
Battery Type: Lead Acid Battery
Wave Form: Simulated Sine Wave
Color: Black
Display: LED Light
Certification: CE ROHS
Transfer Time: 2-6ms
Warranty: 1 Year
Frequency: 50HZ/60HZ
Power factor: 0.6
Packaging Detail: MODEL ST2000 Unit Size 370 x 138 x 166mm Unit weight 11.25kgs Gift box size 470 x 195 x 255mm QTY/CTN 1pcs / ctn Carton Size 470 x 195 x 255mm GW/CTN 14.25kgs NW/CTN 12.75kgs Warranty 12 months

Full protection digital LCD display UPS power supply 2000VA 1200W for education institute

Main Features

♦ LCD display or LED display for option;

Excellent microprocessor control optimizes reliability;

Built super smart charger,shorten charging time;

Boost and buck AVR for voltage stabilization;

Simulated sine wave;

Auto restart while AC is recovering;

Power-on self test;

Built-in self-diagnostic function;

Off mode charging function;

Intelligent battery management;

Optional no-load shut down;

Humanized alarm system;

Compatible with generator set(optional);

Optional RS232/USB communication port and RJ11/RJ45 protection.

 

Specifications

MODELST2000
Capacity2000VA/1200W
INPUT
Voltage110/120 VAC or 220/230/240 VAC
Voltage Range81-145 VAC or 162-290 VAC
Frequency Range60/50Hz (Auto sensing)
OUTPUT
Voltage110/120 VAC or 220/230/240 VAC
AC Voltage Regulation(Bat Mode)±10%
Frequency Range(Bat Mode)60Hz or 50Hz ± 1Hz
Transfer TimeTypical 2-6ms
Waveform(Bat Mode)Simulated sine wave
BATTERY
Battery Type & Number12V 9Ah*2
Charging Ability4-6 hours recover to 90% capacity
PROTECTION
Full ProtectionShort circuit,Overload, Battery discharge and overcharge,Surge protection
INDICATIONS
AC ModeGreen lighting
Battery ModeYellow flashing
FaultRed lighting
Battery ModeSounding every 10 seconds
Low BatterySounding every second
OverloadSounding every 0.5 seconds
Battery Replacement AlarmSounding every 2 seconds
FaultContinuously sounding
Dimension370*135*165mm
Net Weight11.3kG
ENVIRONMENT
Humidity0-90% Relative Humidity 0-40°C (Non-condensing)
Noise LevelLess than 40dB
COMMUNICATIONS
USB/RS232/SNMP(optoions)Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8 Linux Unix and MAC

 

UPS Inner Structure

 

 

STC-11.jpgSTC-12.jpgSTC-21.jpg

frequency ups machine

 

 

Applications

 

                Application use 

Packaging & Shipping
MODEL ST2000
Unit Size 370 x 138 x 166mm
Unit weight 11.25kgs
Gift box size 470 x 195 x 255mm
QTY/CTN 1pcs / ctn
Carton Size 470 x 195 x 255mm
GW/CTN 14.25kgs
NW/CTN 12.75kgs
Warranty 12 months

1 

Company Information

3(1)Why choose Fenice Power

 

Certifications

 

Our Services

1.Warranty

A. Our product warrant is valid for 12 months after the date of receiving.

B. We undertake to repair any malfunctioned units due to defective components of inadequate workmanship.

2.Delivery Time

A. Sample orders will be delivered in 7 working days since full payment received.

B. General orders (under 2000pcs) will be delivered in 25 working days after downpayment received or L/C received.

C. Bulk orders (over 2000pcs) will be delivered in 30 working days after downpayment received or L/C reveived.

3.Shipment

By vessel or by freight,for sample order go by EMS,DHL,FedEx,TNT,UPS or other express.

1.Why choose Fenice Power?

Strong R&D team with 20 years experience on UPS and Inverter; Over 20 years professional power system producing experience; 10 years experience on exporting market.

2. Are you ODM/OEM factory?

Yes,our factory located in Shenzhen,welcome to anytime.

3. What capacity do you have for line interactive ups and inverter?

We have 450VA/650VA/850VA/1000VA/1200VA/1500VA/2000VA for line interactive ups,1200VA/2400VA for inverter. Anyway,you can customize the capacity.

4. Can you ship me a sample?

Yes,sample orders will be delivered in 7 working days since full payment received.

5. Is the product safe and environmental?

Yes,it has overload,overcharge,discharge protection. We got RoHS certification.

6. Do your products have warranty?

Of course. One year warranty after you received the line interactive ups and inverter.

7. Whats the difference of line interactive UPS and Inverter?

Inverter has large capacity,cant supply power immediately. Line interactive UPS has small capacity,can supply power immediately.

FAQ

Frequently Asked Questions
Check out our frequently asked question database for answers. If you can't find your questions or answers here, please contact us and we will get back to you.

What is a UPS?
An uninterruptible power supply, also uninterruptible power source, UPS or battery/flywheel backup, is an electrical apparatus that provides emergency power to a load when the input power source, typically the utility main, fails.
 
Why do I need a UPS?
Power disturbances and blackouts can be costly.  Preserving Information, the availability of equipment critical to the business, maintaining fully occupied staff, reduction of cost over-runs, performing reliably and getting results on time are all key elements in any successful operation.   A UPS will provide clean, stable power to critical application equipment throughout utility power disturbances and power failure.
 
How many types of UPS are there?
There are three typical types of UPS: OFF-LINE, ON-LINE, and LINE INTERACTIVE.
 
What is an " ON LINE UPS ?"
An Online UPS takes incoming power, converts it to DC, conditions it, and converts it back to AC. This means the UPS is Online since there is no delay to switch to battery. Use an online UPS for your critical applications, high availability servers, etc. The output of these online UPS systems are TRUE sine wave, and is usually better than power from the electric company.
 
What is a "LINE INTERACTIVE UPS ?"
An Online UPS takes incoming power, converts it to DC, conditions it, and converts it back to AC. This means the UPS is Online since there is no delay to switch to battery. Use an online UPS for your critical applications, high availability servers, etc. The output of these online UPS systems are TRUE sine wave, and is usually better than power from the electric company.
 

How to choose the right UPS?
1. Understand specifications of all UPS.
2. Consider the requirements of power quality.
3. Understand the current capacity of UPS and consider the future expansion.
4. Choose reputed brands and manufacturers.
5. Choose UPS based on your requirements.
 
What are the important items you should evaluate when buying a UPS?
1. UPS reliability and stability.
2. The excellent engineers and the ability of products creation.
3. High efficiency and low noise.
4. Suppliers' reputation and financial situation.
5. International safety approvals such as TUV,UL,CSA, and so on.
6. Plant certifications such as ISO9001, ISO9002, and so on.
 
Where I live seldom occurs power failure will I still need a UPS?
In fact, power failure is one of power problem. The other power problems such as high voltage, low voltage, and spike are the main problems. The purposes of UPS is to provide customers the overall power protection such as voltage regulation, surge protection, spike, and sags protection. It also provides extended back up time without any limitation.
 
What could I use for the RJ11 connector on the rear panel of UPS?
RJ11 connector is used to protect the phone line. Hence, you can connect your phone; fax machine, modem and ADSL with it for better protection.
 
How many kinds of Power problems?
Except the blackout, there are Sags, Spikes, Surges, Noise & Transients will make the PC or other high technical equipment damage or shorten the lifetime.
 

What kinds of equipment should I use with the UPS? Is there any limit for it ?
Normally, the UPS is used for PC, high technical equipment & medical appliances. Because of most UPS are designed for PC, so not all the equipment could be connected with it. Especially, conducting loads just like cooling fans, refrigerators that have the motors. These kinds of equipment will damage the UPS. Moreover, copy machine and laser printers that have huge starting current also could not be used with UPS. The huge starting current will impact the capacity of UPS.
 
What is the impact of different output waveforms?
There are three major types of loads: Resistive load (Lamps); SPS load (PC power supply) & Conductive Load (Motors). All the types of load can be used with Pure Sinewave. However, only Resistive and SPS loads can be used with Modified Sinewave.
 
What is the impact to the PC with different transfer time?
Except On-Line UPS, there will be a short transfer time between 2ms to 10 ms for the power transformation with OFF-LINE & LINE INTERACTIVE UPS. Normally, when the blackout happens, the power supply of PC could continue the power for 16ms. Hence, most PC will still work functionally with the short transfer time.
 
What is the battery type of UPS?
Most UPS use Lead-acid maintenance-free batteries. This kind of battery is sealed so the UPS can be located with any direction and it does not void the poison gas during charging and discharging. So it also could be an indoor installation.
 
What is the lifetime of batteries?
The battery lifetime depends on the ambient temperature and the times of charging and discharging. Higher ambient temperature and too many charging and discharging times will reduce the lifetime. Normally, the battery lifetime is close to three years.

 

Contact Information

name card.png