Port: | Shanghai/Dalian/Qingdao |
Payment Terms: | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
Supply Ability: | 500 Set/Sets per Month |
Brand Name: | TD8620 |
Accuracy: | ±2% |
Place of Origin: | Shaanxi China |
Scope: | Maximum calibration field 2400 mT, 24 kiloguass |
Dimensions: | 160 mm*80 mm*32 mm |
Storage temperature: | -20℃ ~ 50℃ |
Operating environment: | 0℃ ~ 50℃ |
Range: | 200 mT-2000 mT |
Model Number: | TD8620 |
Weight: | 260 g(include battery and cable) |
Power: | Stud-snap Battery Operated ;one section of 9 V battery |
Display: | 4 digit(in Decimal) |
Resolution: | 10 μT |
Packaging Detail: | One set in one carton box |
TD8620 Handheld Digital Gauss TeslaMeter
The TD8620 Handheld Digital Teslameter is a field-portable unit that measures DC magnetic fields with direct digital readout in mT or G. The unit is designed for wide range, auto-range, high accuracy, and ease of use .
TD8620 includes three grades of meters:
1) Accuracy of TH8620-1 is ±1% of reading;
2) Accuracy of TH8620-2 is ±2% of reading;
3) Accuracy of TD8620-5 is ±5% of reading;
Application:
1) Permanent magnet surface magnetic measurement;
2) Remanent magnetization measurement of mechanical parts;
3) DC magnetic field source measurement;
4) Magnetic field measurement of magnetic separator;
5) Speaker quality control;
6) Working magnetic field measurement of permanent magnet iron remover;
7) Working magnetic field measurement of DC generator;
8) Leakage magnetic field of strong magnetic shielding;
1. Front Panel
TD 8620 front panel key are defined as follows.
1) ON/OFF: Turns power to the unit on/off.
2) Hold: Turn Max Hold feature on and off. Max Hold captures and displays the highest field reading.
3) Turn backlight feature on and off. Backlight lighten up the LCD for reading.
4) NULL: Used to zero or null effects of ambient low level fields from the probe. When user pushes the NULL key ,”0000.0 G or 000.00 mT”displayed. The unit then automatically accepts whatever residual field it reads as a zero offset .
5) mT/G : Changes units from mT to gauss .Gauss is used in the cgs system :1 G=0.1 mT,mT is used in the SI system :1 mT =10 G
2.. Rear Panel
3. Axial and Transverse Probe
CAUTION :Care must be taken when handing the probe .The tip of the probe is very fragile .Pressure the Hall sensor can alter its calibration. Don’t apply more force than is required to hold probe in place. So there is no excessive pressure which will tend to bend or depress the sensor substrate and will destroy the Hall element inside.
4. Connectors
5. Operation
5.1 Turn on meter
Push the On/Off key. The LCD displays parameters as range, polarity, value, unit ,battery indicator, percent of range and so on.
5.2 Gauss/mT
Press the Gauss/mT key to toggles the display between the two units.
5.3 Handing probe
The tip of the probe is very fragile. Stressing the Hall senor alter its calibration. Any excess force can easily break the sensor. Broken sensor are not repairable. The axial sensor is exposed on the end of the probe. A collision with a hard surface can damage the sensor or wear away its protective coating. The transverse sensor is somewhat susceptible to bending stress and erosion of the protective coating.
5.4 Probe operation
For best results , the instrument and probe should warm up for at least 10 minutes before operation.
When magnetic field forward vertical cross the Hall sensor ,the polarity is positive(N) or negative (S)
Probe readings are dependent on the angle of the sensor in relation to the magnetic field. The magnetic field should Vertical cross the sensor. Maximum output occurs when the flux vector is perpendicular to the plane of the sensor. The greater the deviation from vertical orientation, the larger error of reading.
5.5. Hold
The Hold function display the largest field magnitude measured .When the Hold key is pressed, the maximum value is captured and shown in the display.Press the Hold key again, Hold function will be turn off ,the “Hold” is disappear .The meter is real-time measurement of magnetic field.
1. TD8620-1
Range | 200 mT 2000 mT |
Scope | Maximum calibration field 2400 mT, 24 kiloguass |
Resolution | 10 μT |
Accuracy | ±1% |
Display | 4 digit(in Decimal) |
Power | Stud-snap Battery Operated ;one section of 9 V battery |
Operating environment | 0℃ ~ 50℃ |
Storage temperature | -20℃ ~ 50℃ |
Dimensions | 160 mm × 80 mm × 32 mm |
Weight | 260 g(include battery and cable) |
Hall probe | Transverse probe , with 1 m cable |
2. TD8620-2
Range | 200 mT 2000 mT |
Scope | Maximum calibration field 2.4 mT, 24 kiloguass |
Resolution | 10 μT |
Accuracy | ±2% |
Display | 4 digit(in Decimal) |
Power | Stud-snap Battery Operated ;one section of 9 V battery |
Operating environment | 0℃ ~ 50℃ |
Storage temperature | -20℃ ~ 50℃ |
Dimensions | 160 mm × 80 mm × 32 mm |
Weight | 260 g(include battery and cable) |
Hall probe | Transverse probe , with 1 m cable |
3. TD8620-5
Range | 200 mT 2000 mT |
Scope | Maximum calibration field 2400 mT, 24 kiloguass |
Resolution | 10 μT |
Accuracy | 0~1000 mT:±2% 1000 mT ~ 2400 mT:±5% |
Display | 4 digit(in Decimal) |
Power | Stud-snap Battery Operated ;one section of 9 V battery |
Operating environment | 0℃ ~ 50℃ |
Storage temperature | -20℃ ~ 50℃ |
Dimensions | 160 mm × 80 mm × 32 mm |
Weight | 260 g(include battery and cable) |
Hall probe | Transverse probe , with 1 m cable |
Q: Are you trading company or manufacturer ?
A: We are factory.
Q: How long will you give me the reply?
A: We will contact you in 8 hours as soon as possible.
Q: How long is your delivery time?
A: Generally it is 3-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock, it is according to quantity.
Q: Do you provide samples ? is it free or extra?
A: Yes, we can provide you a sample in a relatively favorable price.
Q: Could I be your agent?
A: Of course, we sincerely invite you to be our agent and provide products training.
WHO ARE WE?
Smagall is a brand for liquid level product series and magnetic product series in Xi’an Huashun Measuring Equipment Co.,Ltd. For nearly 20 years, Smagall has designed and manufactured a broad range of liquid level sensors, meters, switches, Fluxgate sensor series and Magnetic sensor calibrating systems.
Smagall enables industrial manufacturers, municipalities and chemical distributors to safely and efficiently manage their contained liquid assets. Our quality solutions measure tank inventories, ensure workplace safety and protect the environment. We design, manufacture and market the best level measurement and control instruments for hazardous chemical applications.
WHY SMAGALL?