Skin Whitening Rejuvenation Device Pigment Removal Machine ND Yag Laser Q-Switch

$1,200.00
1 Unit
$1,100.00
>=2 Units
Min. Order
1 Unit
GET LATEST PRICE ON APP
Coupons
$20.00 OFF
Choose your specifications
Company Information

Shenzhen SureBeauty E-Commerce Co., Ltd.

CN Trading Company, Distributor/Wholesaler
Response Time
<24h
Response Rate:
88.7%
Transactions
US$ 70,000+
2 Years Paid Supplier Gold Supplier Onsite Check Trade Assurance
Learn More

Quick Details

Port: Shenzhen
Payment Terms: T/T,Western Union,paypal
Supply Ability: 500 Unit/Units per Week
Handpiece: 1 pcs
Keywords: tattoo removal
Place of Origin: Guangdong China
Laser Type: Nd: Yag Laser
Q-Switch: Yes
Service: ODM OEM
Model Number: HR-FA50
Feature: Pigment Removal,Whitening,Skin Rejuvenation,Tattoo Removal
moq: 1 unit
Certification: CE ROHS
Brand Name: no brand
Type: Laser
Technology: Yag LASER
Function 3: 2000mj laser for fast treatment result
Function 2: 500W Power
Style: Portable
Function 1: RED Target Light
Function 5: Black doll for skin whitening,rejuvenatioon
Function 4: Remove tattoo, lipline, eyebrow, birthmark
Packaging Detail: Net weight:12.55 KG Gross Weight:21.25 KG Product Dimensions: 51*31*36 CM Packing Size: 61*41*45 CM

01

Skin Whitening Rejuvenation Device Pigment Removal Machine ND Yag Laser Q-Switch

 

Operation Theory:

Adopting the Q-Switch ND YAG model,the equipment uses YAG to emit high energy instantaneously which smashing the pigment of pathological tissues,namely the YAG leading explosive effect:High energy emits instantaneously,making particular wavelength penetrating epidermis and getting into pathological pigment tissues in only 6 nms. Then pigments expand in top speed and explode.The superficial epidermis would be bounded our of body;other part of the pigments would split into granules which would be engulfed by macrophages,then exclude by the lymphatic system finally.The pigment becomes shallow gradually finally disappear while the surrounding normal skin tissues keep sound as they do not absorb particular wavelength .

 

Operation Range:

1.Pigment skin pathological changes,pigmentation caused by color pigment mixture,corium spot,freckle,mole,birthmark,nevus of Ota,etc.
2.Specialized in removing red capillary,coffee,brown and other colorized tattoos.
3.Effectively remove all kinds of embroider eyebrow,soak lip,eye line,and lip line.

 

Application:

The system gem-adjusting Q switch can effectively cure the mixed pigments by pigment precipitation of extraneous source with pathological pigment change of endogenous source, inclusive of erroneous dark eyebrow-embroidery, lip-embroidery, lip-soak, eye line-embroidery, lip-line, tattoo (inclusive of tattoo by extraneous wounds), pigment precipitation by sensitive source, freckle on female's face (male's), coffee spot, old age spot, black mole, and birthmark in black, blue, purple, brown, red and etc. Operation course for different illness case as follows:
Operations
Operation course required ( cure times)               Operation course interval                   Remark (requirements in surgery) 
eyebrow-embroidery(eyeliner grain)              1-2 times                                                              30-60 days                                          Eyebrow blow, eyeball protection 
Eyebrow-embroidery ( eyeliner embroidery)  1-3 times                                                                45-60 days                                          Eyebrow blow,  eyeball protection 
Lip line (red dyed lip)                                       1-3 times                                                                15-45 days                                          Use 532 filter 
Tattoo(caused by extraneous wounds)         1-4 times                                                                30-60 days                                         Blood infiltration will be fine on wounds
Freckle, age spot                                            1-4 times                                                                 15-30 days                                          Blood infiltration will be fine on wounds
Birthmark, nevus/mole                                     3-7 times                                                                 45-90 days                                         Must  have  Blood infiltration . 

1. Operation for tattoo in eyebrow
Customer could not open eyes during Operation, operator should adjust energy according to depth of tattoo color, hold the handle and move it to Operation area slowly to make customer feel acceptable in mentally. Right now, the speed of flash could be set 3HZ, keep head of the handle a two-finger distance to Operation area, start Operation from head of eyebrow to end of eyebrow. It is needed to treat again in 5-10 minutes if the color of tattoo re-appear.

2. Remove eye line 
The speed of flashes could be set 4-5HZ,adjust the energy of light to minimum energy, keep a one-finger distance between head of handle and Operation area. Operator should strictly protect customers eyes with panel for eyelid or medical pledget (panel for eyelid)of 1cm depth.
Operation should be started from down eye line, customer should deeply close eyes and keep eyeball up-sight inside. Operator should press the pledget (panel for eyelid) with forefinger and push up eyelid, peel down eyelid with middle finger to bare the eye line, treat it with flashes of 4-5Hz. Then, treat up eye line. Also customer should close eyes and keep eyeball down-sight inside. Operator should press the pledget (panel for eyelid) with middle finger and push eyelid down, push eyelid up with forefinger to bare the eye line, treat it with flashes of 4-5Hz.

3. Remove lip line
The speed of flashes could be set 5Hz,keep a 3/4 finger distance between head of handle and Operation area. It is better to remove black, coffee, deep, red and brown lip line with 1064 head at first time and then, treat again with 532 head.
Notice: All tattoos in lip should be treated in 6 months after making. OR removal Operation will fail. It should have 45-60 days interval to continue next Operation until remove all. 

4. Remove tattoo
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for Operation until Operation area seeps a little blood. It should have 45-90 days interval to continue next Operation until remove all.

5. Remove spot and nevus
The speed of flashes could be set 3Hz/5Hz. Keep 3-4 fingers distance between head of handle and Operation area. It is better to use high energy for Operation until Operation area seeps a little blood. It is advised to use 1064 head for normal spot and nevus Operation, but for deep color spot and nevus, it is better to use 532 head for Operation. It should have a 15-30 days interval to continue next Operation until remove all. 

6. Remove birthmark
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for Operation until Operation area seeps a little blood. It is advised to use 1064 head for birthmark Operation, but for red and deep color birthmark, it is better to use 532 head for Operation. It should have 45-90 days interval to continue

 

Specification:

Cooling condition: wind system+closed circulating+cooling system   
type: Q-switch Nd YAG  With RED target light to aim at the skin.
The pulse energy: 0~2000mJ   
Frequency:1-5Hz continuous adjustable
Dimension: 530*340*340(mm)
Power: 500W
Tips: 1064 nm & 532 nm and black doll tips

 

Packing List:

1 x Main Unit
1 x Hand-piece
2 x Tips
1 x Black doll tip
1 x Water funnel
1 x Foot touch
1 x Protective goggle
2 x Goggles (1 for operator, 1 for customer)
1 x Power line (we stock 110V-240V power version and US.UK.UA.EU plugs for the country all of the world)

 

6543x1x4x6x2x3x5

 

 

0405