8m3/hr Single Chamber Mini Pocket Pond UV Sterilizer for Fish Farm

Note: Please be cautious and check with your supplier if this product is for virus protection purposes and if the coronavirus (COVID-19) will affect your order.

Quick Details

Condition: New
Place of Origin: Guangdong China
Warranty: 1 YEAR
Local Service Location: None
Ballast: Special make
Size: L.105*W.40* H45cm,L.105*W.40* H45cm
After-sales Service Provided: Video technical support,Field installation, commissioning and training,Field maintenance and repair service,Free spare parts,Online support
Material: Rubber Seal
Showroom Location: None
Weight: 15
Brand Name: CAT-AQUA
Water Input/Output Size: 63mm
Applicable Industries: Farms,Aquaculture
Capacity: 8m3/hr
Product name: Industrial uv sterilizer devices uv sanitizer sterilizer for RAS
Body Materials: UPVC
UV Sterilizer Power: 160watt
After Warranty Service: Video technical support,Online support
Lamp: Philipps-Industry Class Single 4pin
Application: Water Treatment, RAS, Aquarium
Power: 160watt
Max Pressure (Mpa): 0.6Mpa
Packaging Detail: Industrial uv sterilizer devices uv sanitizer sterilizer for RAS in pallets fixed with Wooden box, plastic film, WOODEN CASE and steel band or as your special requirement.
Selling Units: Single item
Single package size: 150X37X37 cm
Single gross weight: 40.0 KG
Package Preview: https://sc01.alicdn.com/kf/HTB1YQsofnZmx1VjSZFGq6yx2XXaP.jpg_640x640.jpg
Xiamen Chongrui Aqua Technology Co., Ltd.
Gold Supplier
CN
Manufacturer, Trading Company
88.2%
Response Rate
0.0%
On-time delivery rate
-
-
Transactions
-
Employees
-
R&D staffs
-
Patents
Visit Store
Product Description
Item
Model
Water Flow(m3/h)
Shell
Power(W)
In/output interface
1
CAT-UV-2T39-1
2T/H
UPVC
39*1
63
2
CAT-UV-4T39-2
4T/H
UPVC
39*2
63
3
CAT-UV-8T39-4
8T/H
UPVC
39*4
63
For big capacity, solo chamber type is preferred with high efficient, low water resistance, easier maintenance, and Low failure rate (most of the time the water flow can not be surely averagely fully filled in muiti-tube UV, that the lamp get easily broken)
Item
Model
Water Flow(m3/h)
Shell
Power(W)
In/output interface
4
CAT-UV-20T39-5
20T/H
UPVC
39*5
75
5
CAT-UV-25T39-6
25T/H
UPVC
39*6
75
6
CAT-UV25T80-3
25T/H
UPVC
80*3
75
7
CAT-UV-30T80-4
30T/H
UPVC
80*4
75
8
CAT-UV-35T80-5
35T/H
UPVC
80*5
75
9
CAT-UV-40T80-6
40T/H
UPVC
80*6
90
10
CAT-UV-50T80-7
50T/H
UPVC
80*7
90
11
CAT-UV-60T80-8
60T/H
UPVC
80*8
110
12
CAT-UV-70T155-5
70T/H
UPVC
155*5
110
13
CAT-UV-80T155-6
80T/H
UPVC
155*6
110
14
CAT-UV-90T155-7
90T/H
UPVC
155*7
110
15
CAT-UV-100T155-8
100T/H
UPVC
155*8
110

Know What You Are Purchasing - All Quotes Are Not Equal

One of the primary jobs the sales and marketing team at CAT-AQUA has with relation to UltraViolet (UV) water treatment systems-is customer education. 'Why is that?' you may ask. Unfortunately, while the concept of UV treatment appears simple, the actual application of the technology is anything but. In fact, capable OEM suppliers take great care to ensure that the customer is able to meet their actual treatment needs, in all practical operational scenarios, today, and as the system ages.

In many cases a potential customer may notice that one quote for a UV product may come in at a significantly higher cost than that of another. Good news, right? Lowest bid wins!

Well, perhaps the company that provided the lowest bid wins, but the real loser may be the customer. In the UV treatment industry, as in many others, it is the hidden or unknown factors that can greatly impact whether your system actually delivers the intended UV dose, or 'treatment', or not. In fact, UV water treatment is such a complex technology that the USEPA and other regulatory bodies worldwide have standardized sizing and application regulations for municipal drinking water and waste water.

UV treatment - Basics you need to know about UV-C and UV Dose

As with any technology, fundamental knowledge is key to understanding the products you purchase. As a customer, being an expert in a given technology is not required. However, the more knowledge you have, the more likely you are to be a satisfied customer. To that end, it may be helpful to explain some of the key areas of interest with regards to UV water treatment.

UV Spectrum - There are four primary parts of the UV spectrum: UV-A and UV-B can make it through the earth's atmosphere. UV-C and UV Vacuum are blocked by the earth's atmosphere. In disinfection typically only UV-C is used.

Figure 1 - Spectrum of Light

UV-C Intensity - The amount of UV-C light that is emitted by a light source is called the 'lamp intensity'. This is typically listed as mW/cm2. UV-C for disinfection is usually measured only at the wavelength of 254nm and is not visible to the human eye.

UV-C Dose - This is fairly easy to understand. It is the lamp intensity (mW/cm2) x time. Dose units are typically listed as mJ/cm2. Lamps with higher UV-C intensity can have the target organisms exposed to light for a shorter period of time than would lower power lamps, for the same overall dose. They both are equal in effectiveness; if the final delivered dose is the same. Contrary to popular belief, UV-C is not used to 'kill' organisms at the doses commonly prescribed. Organisms are inactivated by UV and are not able to reproduce-a harmful bacteria that cannot reproduce does no harm. It so happens that UV-C photon energy has the capability to inactivate organisms over a broad range of the spectrum, with 262nm being at the peak of this curve. The closer the light energy wavelength is to 262nm, the more effective the photons are at inactivation. The accepted wavelength range for disinfection is typically from 220nm-to-280nm.

Okay, so now we know that UV-C, particularly at 254nm, can inactivate organisms. But do all organisms need the same dose to be inactivated? No, they do not. Figure 2 lists some common 'Dose Response Curves' of organisms of concern.

ALGAE
UV DOSE
Chlorella vulgaris
22 mJ/cm2
BACTERIA
UV DOSE
Aeromonas salmonicida
3.6 mJ/cm2 (log-3)
Pseudomonas fluorescens (fin rot)
11 mJ/cm2 (log-3)
Listeria monocytogenes
16 mJ/cm2 (log-5)
Streptococcus sp. (seawater)
20 mJ/cm2
Bacillus subtilis (spores)
22 mJ/cm2 (log-3)
Vibrio anguillarum
30 mJ/cm2
Yersinia ruckeri
30 mJ/cm2
BKD (Bacterial Kidney Disease)
60 mJ/cm2 (estimate)
Flavobacterium psychrophilum (Salmonid Bacterial Coldwater Disease)
126 mJ/cm2
Vibrio sp. (oyster)
155 mJ/cm2
FUNGI
UV DOSE
Saprolegnia diclina (zoospores)
40 mJ/cm2 - 170 mJ/cm2
PROTOZOA
UV DOSE
Sarcina lutea (Micrococcus luteus)
26 mJ/cm2 (log-3)
Ceratomyxa shasta
30 mJ/cm2 (log-3)
Perkinsus marinus (dermo disease)
30 mJ/cm2
Trichodina sp.
35 mJ/cm2 (log-3)
Myxobolus cerebralis (TAMs, Whirling Disease)
40 mJ/cm2
Ichthyophthirius multifiliis (freshwater white spot)
100 mJ/cm2
Amyloodinium ocellatum
105 mJ/cm2
Trichodina nigra
159 mJ/cm2
Cryptocaryon irritans (marine white spot)
280 mJ/cm2
Costia necatrix
318 mJ/cm2 (log-3)
VIRUS
UV DOSE
KHV (koi herpesvirus)
4 mJ/cm2
ISA (Infectious Salmon Anemia)
8 mJ/cm2
CCV (Channel Catfish Virus)
20 mJ/cm2
IHNV (Infectious Hematopoietic Necrosis/CHAB)
20 mJ/cm2
OMV (Oncorhynchus masou Virus)
20 mJ/cm2
IHNV (Infectious Hematopoietic Necrosis/RTTO)
30 mJ/cm2
VHS (Viral Hemorrhagic septicemia)
32 mJ/cm2
CSV (Chum Salmon Virus)
100 mJ/cm2
AHNV (Atlantic Halibut Nodavirus)
105 mJ/cm2
IPNV (Infectious Pancreatic Necrosis Virus)
246 mJ/cm2
Log-1 = 90%, Log-2 = 99%, Log-3 = 99.9%, Log-4 = 99.99%, Log-5 = 99.999%

UV doses not accompanied by a specific log value, should be considered a minimal dosage. The listed data was collected from various sources and RK2 Systems, Inc. does not accept any responsibility for the accuracy of this information. This information is meant to be a guideline and should be used as such.

The collimated beam is a laboratory device designed to deliver precise doses to the samples of the organism in question. The dose response curves are generated by exposing the organisms of concern to various doses. The dose, in mJ/cm2, that was used to reduce the number of organisms logarithmically, is then determined. A viable organism, or one that is not inactivated, is identified after exposure, as it does reproduce. The inactivated organisms do not reproduce. By comparing the inactivated to still active organism, we can understand the reduction in viable organisms in our water. For example, if a liter of water had 10,000 viable target organisms and you delivered a three-log reduction, you would now have 10 viable organisms - 10,000 to 1,000 (one log) to 100 (two log) to 10 (three log).

UV Treatment - Applying the Photons

Now that you understand UV-C, UV Dose and log reduction, we will discuss UV system light sources. There are some key factors that you should be aware of when selecting a specific lamp type in a UV treatment system.

Mercury has been safely used in UV lamps for over a hundred years. In fact, it is very likely that the water you drink every day, whether it be from a tap or a bottle, was treated by a UV system. Mercury is used in lamps because the mercury emits photons, primarily at the 254nm wavelength (nm is short form for nanometer) when excited by an electrical discharge - and this 254nm emission is right near the peak of microbiological inactivation for most organisms of concern.

There are two families of mercury-based lamps used in disinfection - monochromatic lamps that emit primarily at 254nm, and polychromatic lamps that emit with a broad spectrum, where the usable disinfection wavelength range is from 220nm to 280nm. Low-pressure, low-pressure high-output and amalgam lamps are all considered monochromatic in output. Medium-pressure lamps are considered polychromatic.

Lamp efficiency is overlooked by many people, however, if electrical power consumption is important to you, you may want to consider this factor. Lamp efficiency is the ratio of the amount of UV-C output of the lamp, as compared to the electrical input. Efficiency can range from ~35 percent or more for some light sources, to as low as a few percent for others.

Recommend Products
Product packaging
Our Company

CAT-Chongrui Aqua Technology Co.,Ltd

as the most professional one stop RAS manufacture, designer and consult company, offer the best quality reliable goods to our honored customers that through the whole world, CAT-AQUA people always spend 100% hard work try to offer customer the best goods and services.
As professional and leading manufacturer over 20 years. Produce and export high quality Recirculating Aquaculture System (RAS) units which have a very high reputation among our customers. 

Certifications
FAQ
Q: WHAT ARE YOUR FACTORY'S MAIN BUSINESS & PRODUCTS ?
A: Main Business: Advanced RAS design, units production, delivery, installation and training for the Ocean Park, Aquarium, Modern Fish farm, Lab Room and all other related products:
1.Mechanism Filter like SAND FILTER ,DRUM FILTER, BAG FILTER, CARTRIDGE FILTER, CRAWLER MICROFILTER etc.
2.Protein Skimmer with Fresh water model & sea water model, and also the simple type & advanced model
3. Bio-filter, multi types like Bed type (Move Bed & Fix Bed), Bucket type, Cone type
4.UV-Sterlizer, PVC body and Stainless steel ones
5. Ozone Generator & Oxygen Generator
6. PP & FRP fish Tank
7. Incubators
8.Truck Modified
9.Mobile Trailer
10. Lab Aquaculture system
11.Other related goods

Q: HOW LONG AND HOW TO GET SAMPLE FROM US ?
A: 1. We can make as per your request, please provide us artwork in PDF to follow, you only need to pay for the transportation freight and the products sample cost, but once bulk order placed, we will refund you the sample cost.
2. Sample lead time: about 15 days.
3. Sample payment: we accept sample payment sent by West Union, paypal, T/T.

Q: HOW TO ORDER?
A: Please send us your inquiry by E-mail, our sales person will reply you very soon and learn your request. We may take some time for communication to confirm the proposal and then we would make a quotation or proposal for you to place the order:
1.Production information: Quantity, Specification (size, material, color, logo and packing requirement), Artwork or Sample will be the best for us to develop for you.
2. Lead time required.
3.Shipping information: Company name, Address, Phone number, Destination seaport/airport, nominated forwarder contacts.

Q: WHAT IS YOUR TERMS OF PAYMENT ?
A:Payment<=1000USD, 100% in advance. Payment>=1000USD, 30% T/T in advance ,balance before shippment.
Payment recommend according to the Alibaba platform as you can pay by credit card, but if you prefer other ways like TT, west union, Money Gram, Credit Card are all acceptable.

If you have another question, pls feel free to contact us.