GADA MT series low voltage 4P ac uc 385v 3 three phase in 30ka lightning protection electrical equipment surge spd

Note: Please be cautious and check with your supplier if this product is for virus protection purposes and if the coronavirus (COVID-19) will affect your order.
Trade Assurance
Built-in order protection service in alibaba.com
Product quality
On-time shipment
More on shipping and other trade services.

Quick Details

Brand Name: GANDIAN
Voltage protection level(Up): ≤1.4KV
Nominal discharge current(In): 30KA
voltage waveform: 8/20μs
Place of Origin: Zhejiang China
Warranty: 1year
Maximum discharge current(Imax): 60KA
Quality: be best
Maximum continuous operating voltage(Uc): 280V/385V(can be customization)
Color: White and bule
Contact Material: PA66 nylon material and PBT engineering plastics
Model Number: G2060MT-4P
Certification: CE,CQC
Packaging Detail: 24PCS/PKG
Selling Units: Multiple of 24
Package size per batch: 34X34X17 cm
Gross weight per batch: 11.8 KG
Gandian Lightning Protection Electric Co., Ltd.
Supplier
CN
Manufacturer, Trading Company
83.3%
Response Rate
100.0%
On-time delivery rate
US$ 50,000+
24
Transactions
-
Employees
-
R&D staffs
-
Patents
Visit Store
Product Categories
Product Description

G2040MT.jpg

 

 

G2060MT series series secondary power surge protectors are designed according to IEC and GB standards. The products with powerful surge release capability, each of the maximum discharge current 20~80kA(8/20μs), applicable to low-voltage distribution system protection at all levels, according to different distribution systems (TT/TN/IT) can choose a variety of combinations.

Congratulations you found us a professional factory.   Contact us directly: Contact Supplier

About product details as follow:

Product capability parameter

Product model

G2020MT

G2040MT

G2060MT

G2080MT

Pole

1p,2p,3p,4p

1p,2p,3p,4p

1p,2p,3p,4p

1p,2p,3p,4p

Rated frequency

One port

One port

One port

One port

SPD category

Combined type

Combined type

Combined type

Combined type

Test category

Class test

Class test

Class test

Class test

Rated voltage Un

220V AC 50~60Hz

220V AC 50~60Hz

220V AC 50~60Hz

220V AC 50~60Hz

Maximum continuous operating voltage Uc

385V AC 50~60Hz

385V AC 50~60Hz

385V AC 50~60Hz

385V AC 50~60Hz

Nominal discharge current ln(8/20μs)

10kA

20kA

30kA

40kA

Maximum discharge current lmax(8/20μs)

20kA

40kA

60kA

80kA

Voltage protection level Up(8/20μs)

1.45kV

1.6kV

1.8kV

2.2kV

Fuse or circuit breaker / backup protector

20A/60kA

25A/60kA

32A/80kA

32A/80kA

Response time tA

≤25ns

≤25ns

≤25ns

≤25ns

Size

72x90x69

72x90x69

72x90x69

72x90x69

Failure indication

Green: Normal Red: Failure

Sectional area of wires

6~25mm2

Installation method

35mm standard rail (EN50022/DIN46277-3)

Working environment temperature

-40~85

Sheathing material

Plastic

Protection level

IP20

Authentication

CQC CE Type test

Remote alarm

Normally open / normally closed contact terminal (optional)

Remote signaling interface wiring capability

Maximum 1.5mm2 single strand/soft wire

Almost all the parts of product are produced by our own work, better quality control, competitivly price, timely deliver. We are the factory! we are the source!


092A1902-(3)_01.jpg

lt is the product you are looking for, and click to send an inquiry!

Detailed Images

 

092A1902-(3)_02.jpg

092A1902-(3)_03.jpg

Need to be customized, please click send more requirements!

Certifications

_03.jpg 

Related Products
Company Profile

_06.jpg

 

_08.jpg

_07.jpg


 

FAQ

-_09.jpg

Q1: Selection of surge protector

Al: The grading of the surge protector (commonly known as lightning protection) Is assessed according to the IEC61024 subdivision lightning protection theory, which is installed at the junction of the partition.Technical requirements and functions differ. The first-stage lightning protection device is installed between the 0-1 zone, high for the flow requirement, the minimum requirement of GB50057 is 12.5 ka (10/350), and the second and third levels are installed between the 1-2 and 2-3 zones, mainly

to suppress the overvoltage.

Q2:Are you a lightning surge protectors factory or lightning surge protectors trading compan?

A2: We are lightning surge protectors manufacturer.

Q3: Warranty and return:

A3:1. lightning surge protectors products and accessories have been tested by 3 times before ship out.

  2.We own the best after-sale service team, if any problem happens, our team will do our best to solve it for you. 

Q4: How can I get some lightning surge protectors samples?

A4: We are honored to offer you lightning surge protectors samples, pis contact our staff and leave detailed contact information, we promise to keep your information confidential.

Q5: Is sample available and free?

AS: Sample is avaible, but the sample cost should be pay by you.The cost of sample will be refund after further order.PV type Solar spd device surge arrester equipment 2pole pv spd

Q6:Do you accept customized order?

A6:Yes, we do.

Q7: What's the delievery time?

A7:It usually takes 7-15days after confirming payment, but specific time should be based on the order quantity. 

Contact us

 Contact us