Quick Details

Port: Tianjin
Payment Terms: L/C,T/T,Western Union
Supply Ability: 3000 Unit/Units per Month
Airflow: 32000
Condition: New
Cooling capacity range: 27.4~605.1Kw
Warranty: 1 Year
Place of Origin: Beijing China
Double skin panel: 25/50mm PU insulation
Refrigerant: R410a
After-sales Service Provided: Free spare parts,Video technical support,Field installation, commissioning and training,Field maintenance and repair service,Online support,Engineers available to service machinery overseas
Certification: SGS
Brand Name: Holtop
Mounting: Ceiling Mount
Function: Air Conditioner Terminal Unit
Type: Air Handling Unit
Applicable Industries: Hotels,Garment Shops,Building Material Shops,Machinery Repair Shops,Manufacturing Plant,Food & Beverage Factory,Farms,Restaurant,Retail,Food Shop,Printing Shops,Construction works ,Energy & Mining,Food & Beverage Shops,Advertising Company,HVAC
Filter: F7+F9+F13
Operating Voltage: 380/400 VAC
Fan type: AC belt drive fan/EC fans/plug fan
Application: Heat recovery,adjust cold/heat/humidity
Heating capacity range: 30.7~663.9Kw
Packaging Detail: Plywood pallets;plywood case
Package Preview: https://sc02.alicdn.com/kf/HTB19AcmU4TpK1RjSZFK7612wXXaM.png_640x640.png
Beijing Holtop Air Conditioning Co., Ltd.
Gold Supplier
CN
Manufacturer, Trading Company
94.9%
Response Rate
100.0%
On-time delivery rate
US$ 850,000+
18
Transactions
-
Employees
-
R&D staffs
-
Patents
Visit Store
air handling unit design
industrial vertical type air handling unit water cooled packaged unit air handling unit design
Product name
Air handling unit
Material
Stainless steel
Function
Heat recovery,adjust cold/heat/humidity
Application
Home,office,factory,plaza,toilets and other house
Filter class
G4+F7+H10
Place of origin
Beijing,China

 

air handling unit design

 

Selection Table of AHU

air handling unit design

 

Working principle

1/Both supply fan and exhaust fan are built inside tobring in fresh air and exhaust out the stale indoor air as well, thus to keep indoor space in natural comfort.
2/Built-in heat exchanger (rotary heat exchanger or plate heat exchanger) transfers energy contained in the outgoing indoor air to the coming fresh air,thus fresh air is precooled or preheated.
3/Various functional sections such as filter section,cooling/heating section, humidifying section etc.can be combined together to meet different air treatment requirements.

air handling unit design

 

 

Judging left or right type

Look at the direction of airflow supplied to indoor, it’s left type if water pipes are located on the left side of the unit; otherwise, it’s a right type. For standard AHU, service door, wiring port and water pipe locate on the same side.

air handling unit design

 

Main features

1/ Up-down layer construction, concise, compact.
2/ Rotary heat exchanger(RHE) as a basic part. Humidifying section, coil section etc. selectable as per requirements.

 

Typical Combinations

Combination mode 1:
Wheel + Coarse filter (medium filter) + Cooling coil (heating coil)+ Humidification + Fan

Combination mode 2:
Plate heat exchanger + Coarse filter (medium filter) + Mixed air +Cooling coil (heating coil) + Fan

air handling unit design

 

Rotary heat exchanger (heat recovery wheel) is mainly used in building ventilation or in the air supply/discharge system of air conditioning equipment. The wheel transfers the energy (cold or heat) contained in exhaust air to the fresh air supplied to indoor.It’s a piece of important equipment and a key technology in the field of construction energy saving.

 

air handling unit design

 

Rotary heat exchanger section

1. Rotary heat exchanger is composed of heat rotor(wheel), frame, drive system, double purge sector and sealing parts etc..
2. Supply air(SA) passes through half of the wheel, exhaust air(EA) passes through reversely the rest half of the wheel, meanwhile the wheel is rotating driven be the drive system. Thus, the wheel can be self-cleaning.
3. Drain pan is equipped under the wheel, in case condensed water occurs from fresh air in summer or return air in winter when their temperature is decreasing. Meanwhile, make sure the drainpipe is expedite and waterseal is installed.

4. Ice jam might occur on the exhaust side when operating in very cold area, if so, rotary speed reduction or turn-on of bypass is required to ensure safe operation of the wheel.
5. On some occasions with strict cleanness requirement, to minimize the carryover from return air to supply air, exhaust fan shall be placed in the leaving section of the exhaust side to create passive pressure, and the pressure shall be lower than that of supply side, so that the double purge sector can perform more effectively.
6. For easy transportation or easy installation in limit space, the wheel can be cut into segments.
air handling unit design


                     

FAN SECTION

We offer different types of fans such as direct driven centrifugal fan, belt driven DIDW forward centrifugal fan, and belt driven DIDW backward centrifugal fan etc..

 

air handling unit design

 

Air filter

In order to ensure heat exchanging efficiency and cleanness, combination of G3 coarse filter and F5 medium filter is selected as standard configuration in HJK AHU.

air handling unit design

 

 

 

FAQ

1.How we can fast make AHU selection and its solution according to project need?
Holtop has a extensive working experience team on all kinds of AHU solution for any building air quality control no matter project private house or industrial factory. First of all, we need to know the AHU service place, and the room size(it’s could better if AutoCAD drawing is available), as well as the local climate data.

air handling unit design

 

2.What it’s the main feature of Airwoods/Holtop’s air handling unit?
:More than 15 years on manufacturing and development air handling unit with air to air heat recovery devices. Strictly design and produce according to GB/T 1429-2008 and ISO approved quality control with strong team of AHU engineer guarantee quality and performance perfect meet thermal bridge factory TB2, mechanical strength D1 and thermal transmittance T2(En 1886-2007) and air leakage ratio 0.94%(GB/T1429-2008)


3.What successful project your AHU service for?
Airwoods/Holtop AHU has been successful use in the Auto-industrial(Benz, General motors, Geely motors, Greatwall motors,Chery motors etc ), printing factory, green house, mall etc. Our goal is to help you find the high efficiency, low running cost, high performance HVAC solution both in field of commercial and industrial.

 

4.What it’s your delivery time and package?
It’s takes 3 week working day for normal AHU production. Package should suitable for ocean shipping and well protection for AHU with plywood case.

 

Company Information

Holtop Factory

Holtop is one of the best manufacturer in ERV/HRV, heat exchanger and AHU area in China, founded in 2002, areas covered more than 30,000 square meters, turnover of 2012 is 42 million dollars, we have enthalpy testing lab. for products test. As a leader in energy/heat recovery equipments, we cooperate with more than 30 famous companies who located in Europe, the Middle east, Korea, Southeast Asia, Taiwan, etc. supplied equipment to Beijing Olympic and Shanghai Expo 2010, works together with domestic and international brands like Midea, Haier, Hitachi, etc.

air handling unit design

 

Holtop partner

Holtop cooperate with world famous brand or offer OEM service including Hitachi, LG, McQuay, TRANE, Systemair, Aldes, York, Haier, Gree, MHI Group, Midea, Carrier, Dunham-Bush, etc.

air handling unit design

 
Holtop products stand for TOP quality in heat recovery ventilation filed in China, certificated by CE, Eurovent, ISO and other different approved tests like anti-flaming test, anti-mold test, energy saving product test. Etc.
air handling unit design