Port: | Shanghai,Ningbo,etc. |
Payment Terms: | L/C,T/T,Western Union,MoneyGram |
Supply Ability: | 50 Set/Sets per Month |
Free chlorine: | 0.3 to 1.0mg/L |
Brand Name: | YLD |
Place of Origin: | Jiangsu China |
Ratio of desalinization: | more than97% |
Removal ratio for disinfection: | more than99% |
Oxygen consumption: | less than1.5mg/L |
Material of tank: | FRP,SS304/SS316,SS frame |
Pollution index FI: | less than 4 |
Model Number: | YLD-1 |
water flow: | 1000LPH |
Water temperature: | 20 to 35℃ |
Iron content: | less than 0.5mg/L |
PH value: | 7.0 |
Delivery Detail: | Shipped in 10 days after payment |
Packaging Detail: | wooden/plywood packaged cases into container |
Reverse osmosis is referred to as RO, which is under external pressure,the solution of some components in the selective permeation,so as to realize the purpose of desalination, purification and enrichment separation.when it is used in water treatment equipment,it can remove most ions in water,and also the fine particles, bacteriaand organic impurities.it is the water treatment equipment of advanced, economic means.Reverse osmosis is use of high pressure pump continuously to the high salt content water pressure delivered to the RO device,ROdevice comprises a reverse osmosis membrane element and the pressure vessel,input water is divided into low penetration of salt solution and salty liquid.Water enters the concentrated liquid and liquid permeability ratio by regulating valve to control.
Working procedures
01. Tank for raw water
02. Pump for raw water
03. Mechanical sand filter
04. Mechanical activated carbon filter
05. Automatic water softener
06. Ultrafilter(UF)
07. High pressure pump
08. Reverse Osmosis
09. Tank for pure water
10. Qualified pure water
Treatment efficiency of reverse osmosis on ions
Technical parameters
(1) input water quality
Pollution index FI:<4
Oxygen consumption:<1.5mg/L
Free chlorine:0.3-1.0mg/L
Iron content:<0.5mg/L
PH value:7
Water temperature:20-35°C
(2)Application of water quality
Sea water desalination: input water salinity:10000-35000mg/L
Brackish water desalination:input water salinity:1000-10000mg/L
(3)Removal ratio for pollutant
Ratio of desalinization:≥97%
Removal ratio for organics:≥95%
Disinfection:≥99%
Applications
* Perchlorate Removal From Drinking Water
* Nitrate Removal From Groundwater
* Perchlorate Removal From Groundwater
* Raw Water Pretreatment
* Tertiary Wastewater Treatment