Cooling System for Air Compressor

$4,720.00 - $54,280.00
Min. Order
1 Set
GET LATEST PRICE ON APP
Company Information

Wuxi Sanjiu Cooling Equipment Co., Ltd.

CN Manufacturer, Trading Company
Response Time
<24h
Response Rate:
68.8%
Transactions
US$ 280,000+
7 Years Paid Supplier Gold Supplier Onsite Check
Learn More

Quick Details

Port: Shanghai/Ningbo
Payment Terms: L/C,T/T
Supply Ability: 30 Set/Sets per Month
Cooling Capacity: 150000kcal/h
Water flow: 30ton
Fan Power: 1.1kw x 2
Spray pump: 1.5kw
Cooling Air Flow: 13000m3/h x 2
Heat Exchanger Material: Copper tupe
Casing Material: Mg-Al-Zn Alloy Coated Steel
Filler Material: MX75 PVC
Delivery Detail: Shipped in 30 days after payment
Packaging Detail: Standard packing ensures proper protection during transportation

 

GHM Series Cross Flow Closed Water Cooling Towers

GHM Series is of capacities ranging from 25 to 300 tons/unit/hour, finished with alloy (Mg-Al-Zn) coated steel enclosure, stainless steel or copper heat exchange coils, and PVC fills. All raw materials are of virgin grade, with superior anti-corrosion features, and the longest service life in heavy duty environment. The enclosure can be also made in stainless steel 304 or 316L on customers’ request. 
This series is of induced draft type. The cool air is inlet through a large surface of one side of the tower, then directed perpendicularly to the spray water flow through both the heat exchange coils and PVC stuff. Eventually the hot wet air is drawn upwards to the outside through the tower top removing the heat. 
This cross-flow design is of high efficiency but lower initial and long term costs. Installation and maintenance is generally easy and economical. The towers dimensions can be customized to suit standard 20’ or 40’ containers to minimise delivery freight.

Product Description

 

Cooling System for Air Compressor

 

Tech Parameter-Rev1

 

Note: All the data is under the condition of 28℃ wet temperature.

If any change of condition,the data will change.

 

 

Model no.

GHM-30(closed circuit)

Water flow rate

30m³/h, adjustable as different temperature

Cooling capacity

From 65~55to45~35

Water pressure

0.32Mpa

Pipe diameter

Input diameter(mm)

DN80

Output diameter(mm)

DN80

Rated Power

Fan (KW)

1.1X2

Spray pump(KW)

1.5

Material of shell/tower body

Superdyma(imported from Japan)

Material of tupe

SUS304;Red copper

Installation Method

Modular Design,Easy Install

 

 

Raw Material & Main Configuration-Rev1-sj cooling tower

  Closed water cooling tower shell is made in Mg-Al-Zn alloy coated steel, of "SuperDyma" series from company Nippon Steel, originally imported Japan. This special alloy coated steel is much better than galvanized steel in corrosion proof performance.

 paste-pic-dp_uuid_vf2uw

-

 

Application etc-Rev1-sj cooling tower

 

The primary use of cooling towers is to remove the heat absorbed in the circulating cooling water system used in power plants, petroleum refineries, petrochemical plants, natural gas processing plants, food processing plants, semi-conductor plants Etc… So Same Cooled Water Can Be Used Again… Which Saves Precious water …The smallest cooling towers are designed to handle water streams of only a few Liters of water per minute supplied in small pipes like those might see in a residence, while the largest cool hundreds of thousands of Liters per minute supplied in pipes as much as 15 feet (about 5 meters) in diameter on a large power plant.
 
A Cooling Tower is a heat exchange system that removes waste heat from a process system fluid, usually water.Cooling towers are used in both commercial and industrial applications.

Application of cooling tower copy

-Working Theory

 Cooling tower Working principles

 

Packaging & Shipping

 

 

SJ Cooling Tower Loading

Company Information

 

 Certificates-sjcooling

 

4-1-cooling tower

1-

2

 

Our Services

 

 

-Quick response in 12 hours

-Professional and economical cooling solution for every client

-Considerate and complete after sales service


 

FAQ

 

 

Model selection guide-Rev1-sj cooling tower

 

Below information are normally required to know for selection of a most proper tower model and solution:

 

Application:  (Explanations: Where the cooling towers will be used for? e.g. for HAVC system, Air Compressors, Melting Furnaces, etc.)
* Water Flow Rate: /h(Explanations: How many Tons of water required per hour?)
* Inlet Water Temp.: °C(Explanations: Temperature of hot water to be cooled)(also descriped as "water temperature drop")
* Outlet Water Temp.: °C(Explanations: Temperature of cooled water, usually it shall be at least 3~4 °C higher than the wet-bulb temp.) 
* Wet-bulb Temp.: °C(Explanations: Highest wet bulb temp. of the location/area or city to install the tower is essential to know to evaluate the size of towers)
* Power Supply:  (Explanations: 380V/3 Phases is standard, which we could have in stock, but for customized towers, the delivery time could be longer)

 

For easier discussions, 24 hours on line service available: Angela is online: skype: oasanjiu Mob./WhatsApp: 13559666650

 

Many thanks for your interests, and your inquires are always well attended!

 

;