$284.00
Min. Order : 2 Units
$263.00
≥50 Units

TT106 Hot Sell Easy Installation Plant Tools Head Temperature Transducer

Note: Please be cautious and check with your supplier if this product is for virus protection purposes and if the coronavirus (COVID-19) will affect your order.
Trade Assurance
Built-in order protection service in alibaba.com
Product quality
On-time shipment
More on shipping and other trade services.

Quick Details

Protection Level: IP 65
Place of Origin: Liaoning China
Model Number: NCS-TT106-PA
Thermal Resistance Supports: 2-Wiring, 3-Wiring & 4 Wiring
Wire: 2,3 or 4-wire technology
Customized support: OEM
Brand Name: Microcyber
Number of Channels: Single Channel
Sensor Type: Resistance---pt100, etc.
Precision: Absolute error<0.01mA
Working Temperature: -40 ~ +85°c(Temperature Transmitter)
Power: 9VDC-32VDC
Low Temperature Drift: Less Than ±30ppm/°c
High Accuracy: ±0.1°c (pt100, pt1000)
Packaging Detail: 4 Wires Pt1000 Easy Install Head Temperature Transmitter
Selling Units: Single item
Single package size: 10X10X10 cm
Single gross weight: 0.2 KG
Package Preview: https://sc04.alicdn.com/kf/H124cd298318c4b538762e10752c239e2b.jpg_640x640.jpg
Microcyber Corporation
Gold Supplier
CN
Manufacturer, Trading Company
≤7h
Response Time
100.0%
On-time delivery rate
US$ 250,000+
47
Transactions
Visit Store
Product Description
NCS-TT106 Temperature Transmitter supports Profibus PA protocol and multiple temperature sensors. With independent R&D communication controller, it has become a fieldbus temperature transmitter with high cost performance. Based on the same hardware, the temperature transmitter also supports Foundation Fieldbus protocol.
NCS-TT106 uses digital technology, so it can connect with many types of thermocouple and thermo resistive sensors. It has wide range and simple interface between field and control room, which reduces the expense of installation, operation and maintenance.
NCS-TT106 supports HART, FF, and PA protocols. It can be widely used in the petroleum, chemicals, electricity, and metallurgical industries, etc.
Dimension&Structure
Installation
Fieldbus temperature module’s power and bus signal share a pair of cable, and it is called bus cable. It is suggested the user use fieldbus special cable recommended by IEC61158-2.
The signal cable and bus cable cannot share wires or wire slot with other device power wire, and they shall be away from device with high power.
The shielded wires of bus ends shall be connected to the ground.
Via positioning hole, use two screws to install the temperature module to temperature housing or rail.
Features
(1) Connected to the above control system via HART communication device; (2) Only use digital function of HART device, and the fixed current on wire is 4mA; (3) Support 15 devices in the mode of short address.
NCS-TT106 temperature transmitter supports FF Hl, PROFIBUS PA and HART protocoIs and multiple temperature sensors. With independent R&D communication controller, it has become a fieldbus temperature transmitter with high performance.
Specification
RTD Parameter at Normal Temperature(25℃)
Signal type
Suggested range
Accuracy(25℃)
Temperature drift(per ℃)
Resistance Signal
0~500Ω
±0.04Ω
±0.001Ω
0~ 4000Ω
±0.35Ω
±0.015Ω
PT100
-200~850℃
±0.15℃
±0.003℃
PT1000
-200~850℃
±0.15℃
±0.005℃
CU50
-50~150℃
±0.15℃
±0.005℃
CU100
-50~150℃
±0.10℃
±0.003℃
Thermocouple Parameter at Normal Temperature(25℃)
Signal type
Suggested range
Accuracy(25℃)
Temperature drift(per ℃)
mV
-100mV~+100mV
±0.025mV
±0.001 mV
B
500℃~1810℃
±0.77℃
±0.050℃
E
-200℃~1000℃
±0.20℃
±0.025℃
J
-190℃~1200℃
±0.35℃
±0.01℃
K
-200℃~1372℃
±0.40℃
±0.025℃
N
-190℃~1300℃
±0.50℃
±0.015℃
R
0℃~1768℃
±0.75℃
±0.023℃
S
0℃~1768℃
±0.70℃
±0.023℃
T
-200℃~400℃
±0.35℃
±0.015℃
The connection mode of HART smart transmitter can be divided into 4~20mA compatible mode and networking mode.
Application
Company Profile
FAQ
Q: What’s Temperature Transmitter 2-wire zero point calibration configuration? A: For 2-wire measurement, 2-wire zero point calibration can be realized by modifying transducer block TWO_WIRES_COMPENSATION parameter. Q: Can I get the electronic manual? A: Yes, please contact us. Q: What type of cable should I use for wiring? A: Fieldbus temperature module’s power and bus signal share a pair of cable, and it is called bus cable. It is suggested the user use fieldbus special cable recommended by IEC61158-2. Q: Can you provided OEM service? A: Yes, we can, such as communication board, we can also provided fieldbus development toolkit.