$568.00 - $2,580.00
Min. Order : 1 Unit

Single room heat recovery clean room air handling unit with F13 filter

Trade Assurance
Built-in order protection service in alibaba.com
Product quality
On-time shipment
More on shipping and other trade services.

Quick Details

Port: shanghai
Payment Terms: L/C,T/T
Supply Ability: 50000 Unit/Units per Year OEM service is available
Airflow: 30000m³/h
Refrigerant: R22/R407C/R410A/R134A
After-sales Service Provided: Free spare parts,Video technical support,Field installation, commissioning and training,Field maintenance and repair service,Online support
Dimension(L*W*H): customized
Warranty of core components: 1 Year
Function: Cooling Heating Ventilation Humidification Air Purifier
Key Selling Points: Competitive Price
Operating Voltage: 380/400 VAC
Local Service Location: none
Machinery Test Report: Provided
Condition: New
Place of Origin: Shanghai China
Warranty: 1 Year
Air filter: primary , medium efficiency filter and HEPA
Showroom Location: none
Casing: PU
Certification: ce
Brand Name: Venttech
Mounting: Floor Standing
Video outgoing-inspection: Provided
Type: DX and chilled water,Air Handling Unit
Core Components: Motor
Marketing Type: Ordinary Product
Applicable Industries: Hotels,Garment Shops,Building Material Shops,Machinery Repair Shops,Manufacturing Plant,Food & Beverage Factory,Farms,Restaurant,Home Use,Retail,Food Shop,Printing Shops,Construction works ,Energy & Mining,Food & Beverage Shops,Advertising Company
Condenser: copper tube aluminum fin
Capacity cooling: 10KW-300kw
Fan type: Axial Fan
After Warranty Service: Video technical support,Online support,Spare parts,Field maintenance and repair service
Application: Hospital, school, office building, shopping mall
Power: 3N-380V-50Hz
Packaging Detail: wooden package for air handling unit
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Gold Supplier
CN
Trading Company
51.6%
Response Rate
50.0%
On-time delivery rate
US$ 1,000+
2
Transactions
-
Employees
-
R&D staffs
-
Patents
Visit Store
Company Profie
Product Description
Feature: 1, Complying with above China Standard, which is from ARI standard. ISO9001 and ISO14001 qualified. 2, Choose best materials, main components are from China top brand or imported. 3, The modular casing design, easy interchanging each other. easy install,easy transport,easy maintaince. 4, Unique no-cold-bridge design, improve the insulation and air tightness, total air leak rate ≤2.5%; 5, With dynamic balanced double inlet Centrifugal fan, with good air dynamic features, and accurate working, high efficiency, low vibration, low noise etc. 6, High efficient heat exchanger coil, ensure to provide the enough cooling capacity to the unit. And also high efficient breakwater panel is provided if required, water flow in coil ≤3×10-4kg/kg 7, Strong structure, good looking and permanent color. 8, Reasonable inside structure, with the suitable space for maintenance and cleaning. 9, Casing sheet: Provide double-skin construction constructing Sandwich type comprising 0.5mm thick galvanized internal and external skins and with 30mm thick polystyrene insulation of minimum 45kg/m3 density. Good airproof material is use between the casing and the frame to reduce the rate of the air leak. The combined air handling untis are modular designed ,each modular can be used independently and can also work together and company with fan coil units to add refresh air. Not only reduce operation costs and energy saving, but also optimize air quality and create a congnitive indoor space to meet the human health requirements.
Specification
Air cooled direct expansion type air handling unit
unit characteristics
Model: GT-ZKW-()DX
20
30
40
50
65
80
100
Cooling capacity
KW
10.1
15.3
20.3
25.5
32.3
38.6
52.0
Heating capacity
KW
10.3
15.7
20.8
26.1
33.5
39.5
53.2
Supply air volume
M³/h
2000
3000
4000
5000
6500
8000
10000
Margin blast pressure
Pa
200
250
300
300
400
400
500
Power
3N-380V-50Hz


Indoor unit
Blower
Type
High efficient centrifugal fan
KW
0.55
0.75
1.5
2.2
3.0
3.0
5.5
Chilled water coil
(option)
Type
High efficient copper tube aluminum fin
Water flow
(m³/h)
1.7
2.6
3.5
4.4
5.6
6.6
8.9
Segment length
(mm)
300
300
300
300
300
300
300
Heater
Type
Stainless steel tubular electric heater/ Steam heat coil/ Hot water heat coil
KW
6
9
12
18
24
24
30
segment length
(mm)
300
300
300
300
400
400
400
Humidifier
Type
Electrode type/ Steam/ Electrothermic type/ Wet film
KW
3
4
5
8
8
12
12
segment length
(mm)
400
400
400
400
400
400
400
Air filter
Type
Primary filter G4( Middle filter F8 &Nanocrystalline carbon filter)
Noise
dB(A)
60
60
61
62
63
63
65
Size
L (mm)
1800
2000
2000
2100
2100
2200
2400
W (mm)
730
1030
1030
1030
1140
1340
1340
H (mm)
788
788
1115
1115
1115
1115
1420
Weight
KG
140
180
320
400
580
660
800
Outdoor unit
Model: GT-WL-
10
15
20
25
35
40
55
Compressor A
Type
Hermetic Scroll ( Fixed frequency system)
Quantity
1
1
1
1
1
2
2
Input power A
KW
3.4
4.8
6.3
8.0
9.8
12.7
16.1
Compressor B
Type
Hermetic Scroll( Frequency conversion system)
Quantity
1
1
1
1
1
2
2
Input power B
KW
3.3
4.6
6.2
7.7
9.7
12.6
15.6
Refrigerant
Type
R22/R407C/R410A
Mode
Thermal expansion valve/ Electronic expansion valve
Noise
dB(A)
63
63
64
64
65
65
76
Size
L (mm)
850
850
980
980
980
1880
1880
W (mm)
850
850
980
980
980
980
980
H (mm)
1080
1080
1080
1080
1234
1080
1080
Weight
KG
130
135
150
180
220
280
320
Connection Pipe diameter
liquid pipe(mm)
12.7
(9.52)
12.7
(9.52)
12.7
(12.7)
15.88
(12.7)
15.88
(12.7)
15.88*2
(12.7*2)
15.88*2
(12.7*2)
gas pipe(mm)
15.88
(12.7)
19.05
(15.88)
19.05
(15.88)
28.6
(22.23)
15.88
(12.7)
22.23*2
(19.05*2)
28.6*2
(22.23*2)
Note: Cooling condition: indoor dry bulb/wet bulb 27/19 ºC;Outdoor dry bulb/wet bulb 35/24 ºC; Heating condition: indoor dry bulb/wet bulb 20/- ºC;Outdoor dry bulb/wet bulb 7/6 ºC; Air volume, pressure, power in the table is standard parameters. It can be separately designed according to customer's requirements; Chilled water coil as optional parts, according to the customer site requirements configured to double cold source unit; Heater, humidifier, heat recovery device as optional parts, according to the customer requirements configured to the specific form Unit standard USES G4 level filters, according to the customer requirements configured to the other forms; Unit length does not include the function section. Such as heating section humidification secition. Specific details please consult us; Air cooled split type air conditioning unit without refrigerant leaving the factory, refrigerant models need to indicated in the order; Noise data is measured 2 m in the front of the unit , 1.2 m high, when cooling under the standard air volume;  Inside of bracket is R410A refrigerant type connection pipe diameter, the connection copper pipe between the indoor and outdoor unit should within 35 meters.
Chilled water type air handling unit
Application The units are widely used in the air system of many inductries like mechanical ,electronic, textile,medical,chemical,energy and foo inductries ,etc. the units are also ideal solution for restaurants, office buildings,hospitals,theaters,supermarkets and palaestra.
Air handling unit drawing
General comfortable occasion air handling unit Configuration of basic function, early efficient filter and hot coil in air handling units (choose wet membrane humidification), it has the simple and highly controllable size characteristics of the function. Suitable for general building room comfort air conditioning process.
Air handling units for all fresh air occasion Configuration of basic function, primary filter or medium efficiency air filter, cooling coil ( enough margin, meet the needs of extreme conditions), it use steam, hot water heating, or natural gas direct combustion heating section ( high thermal efficiency, low running cost); it also need to set the reheat, can choose the cooling reheat to control humidity and enhance the energy level, or set up the electric heater, to realize thermal compensation again after the summer dehumidification. It mainly meet the aerospace, automotive, instruments and meters, precision machining and other special industry requirements for air quality.
Air handling units for general technology purification occasion The configuration of the function section are: mixed section, cooling section, fan section, primary efficiency filter (G4) section, medium efficiency filter (F8) section. At the same time,it equipped with electric heating, electric humidification, muffler to satisfy high cleanliness, constant temperature and humidity,low noise control cleanliness project. Such as: inspection and quarantine laboratory, electronics factory workshop, biological engineering R&D center, food processing, precision machinery, pharmaceutical processing and storage area and other places which have strict requirements for temperature and humidity, cleanliness.
Air handling units for general technology purification occasion
In addition to the general horizontal units, we can provide several kinds of structure forms of units, such as: vertical, ceiling, roof waterproof, etc.. They can meet the demand of different occasions. Ceiling structure unit can be installed on the ceiling. It is suitable for narrow room air conditioning or the area which has not a special equipment room;Roof waterproof structure unit can be installed on the outdoor roof or outdoor floor. Setting rofessional rainproof device and panel special thermal insulation design unit.
Air handling units for operating room and high clean requirement occasion In addition to the basic function of configuration, with primary efficiency filter or medium efficiency filter, it equipped with electric heating and humidification section. Considering particularity of medical situations, AHU adopt double cold source system ( chilled water + direct expansion) and efficient unhoused centrifugal fan, provide frequency conversion control, in order to satisfy the high reliability requirements.
Air handling units with heat recovery device Can configured with wheel heat recovery device, hot and cold air passes through hot wheel, heat and moisture exchange is carried out by the difference of temperature and steam pressure between fresh air and exhaust air, effective recovery of sensible heat and latent heat in exhaust air, achieve the purpose of energy conservation.Honeycomb structure with aluminum foil carrier and high efficient moisture absorbing coating for heat storage core body of heat exchanger, excellent characteristics of heat storage, moisture absorption and heat transfer, efficiency is higher than 75%.
Can configured with plate fin heat recovery device, so that the cold hot air flow directly through the same heat exchanger, in order to achieve the purpose of heat exchange.The heat exchanger adopts ginning aluminum foil,  corrugated aluminum foil heat exchanger made of heat conductor, no interme-diate heat medium is required,no power consumption,no loss of temperature difference,temperature efficiency is higher than 75%.
Packing & Delivery